Electro Surgical Unit with Vessel Sealing System
MEDILAP 400 PROSEAL+ is a excellent multi functional high frequency Electrosurgical Device with Large Vessel sealing up to 7 mm, for open and endoscopic procedure.
User convenient facilities and settings with large visual overview of touch screen display which makes this device versatile. Confined setting of different modes and their applications comprises in compact lightweight unit due to innovative design. The high tech micro controller electro surgical system sense the density of all types of tissue and control the system to deliver the appropriate amount of energy, results precise cut and seal of tissue structure.
A tissue sensing technology used for all applications to deliver user consistent performance.
Reduce the frequent adjustment of power setting as the tissue changes.
Reduce the risk of collateral tissue damage due to sparkles and charring free power.
Minimize the patient recovery time by performing precise and clean cutting and coagulation.
Minimum RF distortion in other O.T. Equipment.
Patient plate fault monitoring system.
Auto monitoring facility, displays different error codes if any error occurs during use.
Randomized form of spray mode.
Two independent power activation of monopolar output, hand switch operation and foot switch operation.
Separate bipolar generator with foot switch operation or hand (auto) operation, eliminates the need of foot switch while using auto mode.
RATED LOAD | RF POWER (WATTS) | ||
---|---|---|---|
MONOPOLAR CUT | Pure Cut | 500 ohm. | 400 W |
Blend Cut-I | 500 ohm. | 300 W | |
Blend Cut-II | 500 ohm. | 250 W | |
Endo Cut | 500 ohm. | 250 W | |
MONOPOLAR COAG | Soft | 500 ohm. | 150 W |
Force | 500 ohm. | 200 W | |
Desiccate | 500 ohm. | 175 W | |
Spray | 500 ohm. | 120 W | |
BIPOLAR | Bi-Cut | 100 ohm. | 150 W |
Macro | 100 ohm. | 125 W | |
Micro | 100 ohm. | 100 W | |
Std | 100 ohm. | 150 W | |
SEALER | Fine Seal | 300 ohm. | 300 W |
Quick Seal | 200 ohm. | 300 W |
INPUT POWER SUPPLY | |
---|---|
Input Voltage | 180-220V Ac |
Current Fuse | 6 Amps |
SAFETY FEATURES | |
Unit Construction According | IEC-60601-2-2 & 60601-1-1 |
Protection | I |
Unit Type | CF |
Output | All Floating Output |
Nominal Frequency | 470 Khz |
High Frequency | <150uA rms in all output |
Low frequency | 10uA max. |
Weight | 6.5 kg. |
Dimension | 390x130x340(LxHxW)mm. |
INPUT POWER SUPPLY | |
---|---|
Input Voltage | 180-220V Ac |
Current Fuse | 6 Amps |
SAFETY FEATURES | |
Unit Construction According | IEC-60601-2-2 & 60601-1-1 |
Protection | I |
Unit Type | CF |
Output | All Floating Output |
Nominal Frequency | 470 Khz |
High Frequency | <150uA rms in all output |
Low frequency | 10uA max. |
Weight | 6.5 kg. |
Dimension | 390x130x340(LxHxW)mm. |